S13-M.RL 10/0.4kV Oil Immersed Transformer
Category:
Detail
Oil immersed transformer is a new type of high-performance transformer with a more reasonable structure and better performance. Its three-dimensional coiled iron core, due to the equilateral triangle arrangement of its three core columns, has no air gap in its magnetic circuit and is wound more tightly. The length of the three magnetic circuits is the same and the shortest, and the cross-sectional area of the core columns is closer to a circle. Therefore, the performance is further improved, the loss is reduced, the noise is reduced, the three aspects are balanced, and the third harmonic component is reduced. This product is more suitable for urban and rural, industrial and mining enterprise power grid transformation, and is more suitable for combination transformers and prefabricated substation transformers.
The fully sealed transformer eliminates the traditional conservator tank by integrating corrugated tank fins as both heat dissipation components and expansion elements.These fins dynamically expand and contract in response to oil volume variations,ensuring complete isolation from the external atmosphere to prevent oil degradation,insulation moisture ingress,and aging,thereby significantly enhancing operational reliability. The core utilizes premium cold-rolled silicon steel laminations to optimize magnetic flux distribution, effectively reducing noise levels and energy losses.Windings are constructed with high-strength enameled or paper-insulated conductors in cylindrical or disc-type configurations,achieving uniform ampere-turn distribution and robust insulation for exceptional short-circuit resistance.All internal fasteners employ self- locking nuts to withstand vibration during transportation and operation.The tank undergoes phosphating treatment and is coated with a triple-protection layer(anti-humidity,anti-mold,anti-salt spray),making it ideal for harsh environments such as metallurgical plants,mining facilities,and petrochemical complexes.
Notes:
1.Customized products with capacities beyond those listed in the table can be manufactured upon request,with technical parameters tailored to specific requirements.
2.Specialized designs are available to accommodate diverse operationalenvironments.
3.Short-circuit impedance values may deviate from the table specifications based on project needs.
4.The final dimensions of the transformer shall be confirmed based on the approved technical drawings after the contract is signed.
| Capacity (KVA) | HV (kV) | LV (kV) | Vector Group | No-Load Loss (kW) | Load Loss (kW) | No-Load Current (%) | Short-Circui Impedance (%) | Weight | Dimensions | Foundation Installation |
| Total(kg) | L×W×H(mm) | L×W(mm) | ||||||||
| 30 | 9KV~11kV | 0.4 0.69 | Dyn11 Yyno | 0.08 | 0.63/0.6 | 0.3 | 4.0 | 251251 | 735×610×815 740×600×815 | 400×400 |
| 50 | 0.1 | 0.91/0.87 | 0.24 | 320/327 | 760×620×850 765×620×850 | 400×400 | ||||
| 63 | 0.11 | 1.09/1.04 | 0.23 | 349/353 | 760×645×875 | 400×400 | ||||
| 80 | 0.13 | 1.31/1.25 | 0.22 | 414/418 | 805×725×880 | 400×400 | ||||
| 100 | 0.15 | 1.58/1.5 | 0.21 | 468/468 | 1020×675×905 1020×670×905 | 400×400 | ||||
| 125 | 0.17 | 1.89/1.8 | 0.2 | 548/558 | 1055×690×930 1060×695×930 | 550×550 | ||||
| 160 | 0.2 | 2.31/2.2 | 0.19 | 639/641 | 1090×720×955 1100×720×955 | 550×550 | ||||
| 200 | 0.24 | 2.73/2.6 | 0.18 | 763/774 | 1195×805×975 1195×810×975 | 550×550 | ||||
| 250 | 0.29 | 3.2/3.05 | 0.17 | 912/919 | 1270×880×995 | 550×550 | ||||
| 315 | 0.34 | 3.83/3.65 | 0.16 | 1065/1077 | 1360×945×1040 | 550×550 | ||||
| 400 | 0.41 | 4.52/4.3 | 0.16 | 1218/1230 | 1460×1025×1070 | 550×550 | ||||
| 500 | 0.48 | 5.41/5.15 | 0.16 | 1453/1478 | 1610×1165×1110 1610×1170×1110 | 660×660 | ||||
| 630 | 0.57 | 6.2 | 0.15 | 4.5 | 1728/1724 | 1570×1085×1145 1590×1100×1135 | 660×660 | |||
| 800 | 0.7 | 7.5 | 0.15 | 2148/2119 | 1625×1095×1190 1760×1225×1170 | 820×820 | ||||
| 1000 | 0.83 | 10.3 | 0.14 | 2398/2409 | 1650×1140×1225 1725×1215×1225 | 820×820 | ||||
| 1250 | 0.97 | 12 | 0.13 | 3054/3039 | 1800×1255×1275 1795×1250×1275 | 820×820 | ||||
| 1600 | 1.17 | 14.5 | 0.12 | 3533/3518 | 1785×1235×1375 1780×1230×1375 | 820×820 | ||||
| 2000 | 1.36 | 18.3 | 0.11 | 5.0 | 5145 | 2140×1260×1900 | 820×820 | |||
| 2500 | 1.60 | 21.2 | 0.10 | 6420 | 2250×1370×1930 | 1070×1070 |
Other Business
35kV Power Transformer,Capacity:3150 to 20000
35kV Dry-Type Transformer, Capacity Range: 50kVA to 8000kVA
Silicon alloy steel with a silicon content
HXGN-12 Common Box Type Ring Main Unit
Ring Main Unit is a set of transmission and distribution
Low voltage switchgear and control equipment include circuit breakers
HXGN-12 Combined Ring Main Unit
Ring network refers to a circular distribution network
KYN28-12 HV Intermediate Switchgear
Mainly used for switchgear related to power generation
XL-21 Power Distribution Cabine
The power distribution cabinet (box), lighting distribution
I Want to Consult
Are there any areas where you feel particularly satisfied or need improvement while browsing our business? Your consultation or suggestions will directly help us improve our service quality and bring you a more intimate experience.
*Please fill in the above fields (fields marked with an asterisk are required), and we will reply to your feedback as soon as possible.