S13-M.RL 10/0.4kV Oil Immersed Transformer

Oil immersed transformer is a new type of high-performance transformer

Category:

Detail

Oil immersed transformer is a new type of high-performance transformer with a more reasonable structure and better performance. Its three-dimensional coiled iron core, due to the equilateral triangle arrangement of its three core columns, has no air gap in its magnetic circuit and is wound more tightly. The length of the three magnetic circuits is the same and the shortest, and the cross-sectional area of the core columns is closer to a circle. Therefore, the performance is further improved, the loss is reduced, the noise is reduced, the three aspects are balanced, and the third harmonic component is reduced. This product is more suitable for urban and rural, industrial and mining enterprise power grid transformation, and is more suitable for combination transformers and prefabricated substation transformers.

 

The fully sealed transformer eliminates the traditional conservator tank by integrating corrugated tank fins as  both heat dissipation components and expansion elements.These fins dynamically expand and contract in  response to oil volume variations,ensuring complete isolation from the external atmosphere to prevent oil  degradation,insulation  moisture  ingress,and  aging,thereby  significantly  enhancing  operational  reliability. The  core  utilizes  premium  cold-rolled  silicon  steel  laminations  to  optimize  magnetic  flux  distribution, effectively reducing noise levels and energy losses.Windings are constructed with high-strength enameled or paper-insulated   conductors  in   cylindrical   or  disc-type   configurations,achieving  uniform   ampere-turn  distribution and robust insulation for exceptional short-circuit resistance.All internal fasteners employ self- locking nuts to withstand vibration  during transportation  and  operation.The tank undergoes phosphating treatment  and  is  coated  with  a  triple-protection  layer(anti-humidity,anti-mold,anti-salt  spray),making  it ideal for harsh environments such as metallurgical plants,mining facilities,and petrochemical complexes.

Notes:

1.Customized products with capacities beyond those listed in the table can be manufactured upon request,with technical parameters tailored to specific requirements.

2.Specialized designs are available to accommodate diverse operationalenvironments.

3.Short-circuit impedance values may deviate from the table specifications based on project needs.

4.The final dimensions of the transformer shall be confirmed based on the approved technical drawings after the contract is signed.

Capacity (KVA) HV (kV) LV (kV) Vector Group No-Load Loss (kW) Load Loss (kW) No-Load Current (%) Short-Circui Impedance (%) Weight Dimensions Foundation Installation
Total(kg) L×W×H(mm) L×W(mm)
30 9KV~11kV 0.4 0.69 Dyn11  Yyno 0.08 0.63/0.6 0.3 4.0 251251 735×610×815 740×600×815 400×400
50 0.1 0.91/0.87 0.24 320/327 760×620×850 765×620×850 400×400
63 0.11 1.09/1.04 0.23 349/353 760×645×875 400×400
80 0.13 1.31/1.25 0.22 414/418 805×725×880 400×400
100 0.15 1.58/1.5 0.21 468/468 1020×675×905 1020×670×905 400×400
125 0.17 1.89/1.8 0.2 548/558 1055×690×930 1060×695×930 550×550
160 0.2 2.31/2.2 0.19 639/641 1090×720×955 1100×720×955 550×550
200 0.24 2.73/2.6 0.18 763/774 1195×805×975  1195×810×975 550×550
250 0.29 3.2/3.05 0.17 912/919 1270×880×995 550×550
315 0.34 3.83/3.65 0.16 1065/1077 1360×945×1040 550×550
400 0.41 4.52/4.3 0.16 1218/1230 1460×1025×1070 550×550
500 0.48 5.41/5.15 0.16 1453/1478 1610×1165×1110  1610×1170×1110 660×660
630 0.57 6.2 0.15 4.5 1728/1724 1570×1085×1145 1590×1100×1135 660×660
800 0.7 7.5 0.15 2148/2119 1625×1095×1190 1760×1225×1170 820×820
1000 0.83 10.3 0.14 2398/2409 1650×1140×1225  1725×1215×1225 820×820
1250 0.97 12 0.13 3054/3039 1800×1255×1275 1795×1250×1275 820×820
1600 1.17 14.5 0.12 3533/3518 1785×1235×1375 1780×1230×1375 820×820
2000 1.36 18.3 0.11 5.0 5145 2140×1260×1900 820×820
2500 1.60 21.2 0.10   6420 2250×1370×1930 1070×1070

Other Business

35kV Power Transformer

35kV Power Transformer,Capacity:3150 to 20000

Dry-type Transformer

35kV Dry-Type Transformer, Capacity Range: 50kVA to 8000kVA

CRGO Silicon Steel

Silicon alloy steel with a silicon content

HXGN-12 Common Box Type Ring Main Unit

Ring Main Unit is a set of transmission and distribution

GGD LV Switchgear

Low voltage switchgear and control equipment include circuit breakers

HXGN-12 Combined Ring Main Unit

Ring network refers to a circular distribution network

KYN28-12 HV Intermediate Switchgear

Mainly used for switchgear related to power generation

XL-21 Power Distribution Cabine

The power distribution cabinet (box), lighting distribution

I Want to Consult

Are there any areas where you feel particularly satisfied or need improvement while browsing our business? Your consultation or suggestions will directly help us improve our service quality and bring you a more intimate experience. ‌

Submit

*Please fill in the above fields (fields marked with an asterisk are required), and we will reply to your feedback as soon as possible.

Get a Quote

Your consultation will help us provide you with the most accurate quotation information

Submit

*Please fill in the above fields (fields marked with an asterisk are required), and we will reply to your feedback as soon as possible.