BlokSet Prefabricated Intelligent Low-voltage Assembly
Category:
Detail
Industry-Leading Technical Parameters Compliance Standards
IEC 61439,IEC 60529,1EC 60947(Schneider Electric switching components ensure optimal performance )
Seismic Resistance
IEC60068-3-3,GB/T2424.25 (Withstands seismic intensity of 9 degrees)
Arc Fault Protection
IEC61641-V3,GB/T18859(Withstands 85kA/0.5s lpc arc)
Global Certifications
ASEFA Lab Certifed (Meets international & Chinese standards)Rigorous testing by national authorities on critical components.
| Rated voltage/Maximum operating voltage | 10/12kV | |
| Rated current | 630A | |
| Main bus current | Entry cabinet | 630A |
| Exit cabinet | 125A | |
| Rated short-time withstand current | 20kA | |
| Rated short-circuit duration | 4S | |
| Rated peak withstand current | 50KA | |
| Rated short-circuit closing current | (50)80kA | |
| Rated active load breaking current | 630A | |
| Closed-loop breaking current | 630A | |
| Rated cable charging current | 20kA | |
| Rated short-circuit withstand current of grounding switch | 20kA | |
| Rated short-circuit duration of grounding switch | (4)2S | |
| Rated peak withstand current of grounding switch | 50kA | |
| Rated short-circuit closing current of grounding switch | 50kA | |
| Lmin rated power frequency withstand voltage | Phase-to-phase,earth-to-ground,vacuum | 42kV |
| load switch interrupting gap | 48kV | |
| Ratedlightning impulse withstand voltage | Phase-to-phase,earth-to-ground,vacuum | 75kV |
| load switch interrupting gap | 85kV | |
| Mechanical life | Vacuum load switch | 10000times |
| Grounding switch(blade) Isolating switch(blade) | 2000times | |
| Junction current | 3150A | |
Previous
Previous
Other Business
35kV Power Transformer,Capacity:3150 to 20000
35kV Dry-Type Transformer, Capacity Range: 50kVA to 8000kVA
Silicon alloy steel with a silicon content
HXGN-12 Common Box Type Ring Main Unit
Ring Main Unit is a set of transmission and distribution
Low voltage switchgear and control equipment include circuit breakers
HXGN-12 Combined Ring Main Unit
Ring network refers to a circular distribution network
KYN28-12 HV Intermediate Switchgear
Mainly used for switchgear related to power generation
XL-21 Power Distribution Cabine
The power distribution cabinet (box), lighting distribution
I Want to Consult
Are there any areas where you feel particularly satisfied or need improvement while browsing our business? Your consultation or suggestions will directly help us improve our service quality and bring you a more intimate experience.
*Please fill in the above fields (fields marked with an asterisk are required), and we will reply to your feedback as soon as possible.